First Revised Sheet No. 106
Effective Date: August 1, 2004


              GENERAL TERMS AND CONDITIONS
                       (Continued)


12. QUALITY

    12.1 The LNG to be received hereunder for Terminal Service
         shall be merchantable and shall have in its gaseous state:

         (A) A Gross Heating Value of not less than nine hundred
             fifty (950) Btu and not more than one thousand two
             hundred (1,200) Btu per standard cubic foot;

         (B) Constituent elements varying within the following
             percentage limits (in molecular percentage):

             Nitrogen          between 0.00 and 1.40
                    
             Methane           between 84.55 and 100.00

             Ethane            between 0.00 and 9.20
                    
             Propane           between 0.00 and 3.25

             Isobutane         between 0.00 and 0.60
                    
             Normal butane     between 0.00 and 0.75

             Pentanes Plus     between 0.00 and 0.25
                    
         (C) A hydrogen sulfide content not to exceed 0.25 grains
             per 100 cubic feet;

         (D) A total sulfur content of not more than 30 mg/Nm3;

         (E) A mercaptan sulfur content not exceeding 2.30 mg/Nm3;

         (F) No water, carbon dioxide or mercury;

         (G) No active bacteria or bacterial agent, including but
             not limited to, sulphate reducing bacteria or acid
             producing bacteria; and 
             
         (H) No hazardous or toxic substances.

         TLNG shall not be obligated to receive any LNG that does
         not meet these standards.
                 
Back to General Terms and Conditions

Back to CMS Trunkline LNG Tariff Contents


Original Sheet No. 107
Effective Date: August 1, 2003




              GENERAL TERMS AND CONDITIONS
                       (Continued)


12. QUALITY (Continued)

    12.2 The LNG or Regasified LNG delivered by TLNG to or for the
         account of Shipper shall be merchantable Natural Gas and
         shall meet the quality specifications in Section 12.1. 

    12.3 The Regasified LNG delivered by TLNG to or for the account
         of Shipper shall be delivered at a pressure sufficient to
         enter the pipeline facilities.

    12.4 Shipper shall indemnify TLNG from any loss, cost, damage,
         or expense incurred by TLNG as a direct or indirect result
         of Shipper's failure to comply with the provisions of this
         Section 12, except to the extent such loss, damage,
         expense, claim, suit, action or proceeding is the result
         of TLNG's negligence, bad faith or willful misconduct or
         is the direct result of TLNG's deliberate decision to take
         Shipper's nonconforming LNG.
                 